UMG 96RM-PN
Panel-mount analyzer with PROFINET + RCM
The UMG 96RM-PN is built for factory-floor automation networks, with two built-in PROFINET IO-IRT Ethernet ports (plus a switch for line/ring topology) so it sits directly on a machine's PROFINET line alongside PLCs and drives. It's also one of the two RM variants (with the -E) that adds true residual-current monitoring, doubling as an early-warning tool for insulation faults and fire-risk creeping ground faults.
Key Features
- 012× PROFINET IO-IRT Ethernet ports with integrated switch (line/ring topology)
- 02REST/HTTP interface and embedded web server
- 03Integrated residual current monitoring: 2 RCM channels
- 04Harmonics to the 40th order
- 052 optional temperature inputs (PT100/PT1000/KTY83/KTY84)
- 06PROFIenergy profile support; used in automotive, plastics, food, machine building
Applications
- Power Quality SolutionsPower quality problems such as harmonics, voltage sags and swells, flicker, transients and voltage unbalance can occur in electrical systems. They can arise from non-linear loads, sudden load changes, network events and the electrical structure of the facility itself. Poor power quality can cause overheating in equipment, nuisance tripping, energy losses, shorter equipment life and interruptions to production continuity. At EPKOM we use power quality analyzers to measure and monitor LV and MV systems, recording harmonics, voltage events and the other power quality parameters. We evaluate the resulting data against the relevant standards, such as EN 50160, IEC 61000 and IEEE 519, according to the measurement point and the scope of the application. Following measurement and analysis, we apply active and passive harmonic filters, SVG systems, compensation solutions and power quality monitoring systems according to the needs of the facility, helping the electrical infrastructure run more safely, efficiently and stably.
- Energy Monitoring SystemsEnergy monitoring systems measure and analyse electricity consumption continuously, at facility, feeder, department or machine level. Alongside electricity, other energy sources such as water, natural gas and compressed air can be tracked through the same system. Data from Janitza energy analyzers is collected centrally in the GridVis software, where consumption trends, load profiles and energy performance indicators can be followed. Automatic reporting and alarm functions make abnormal consumption and energy losses quick to identify. Energy monitoring systems help to allocate energy costs correctly, to identify inefficient points of consumption and to improve energy performance continuously. They also support ISO 50001 energy management processes and make it possible to track energy performance indicators such as PUE in data centers.
Technical Specifications
UMG 96RM-PN
| Measurement inputs | 4 voltage channels (L-N 300/520V, L-L 520/900V); current rated 5A (0–6A RMS, 120A/1s overload); plus RCM inputs |
|---|---|
| Accuracy class | Power Class 0.5 (IEC 61557-12); active energy Class 0.5S; V/I Class 0.2; harmonics Class 1 |
| Communication protocols | RS485/Modbus RTU; Ethernet/PROFINET (TCP/IP, Modbus/TCP port 502, ICMP); embedded web server |
| Display | Backlit LCD, 2-key operation; energy counter 0 Wh–999 GWh |
| Installation type | Panel mount, 104×110.5×72 mm, cut-out 92×92 mm, ~380 g |
| Harmonics | 1st–40th order, flicker (Pst/Plt) |
| Residual current monitoring (RCM) | 2 RCM channels, rated 30 mA RMS (0–40 mA range), Type A per IEC/TR 60755, 50 µA trigger, 1 µA resolution |
| Certifications / standards | UL listed; PROFINET certified (IEC 61158/PROFIenergy); IP40/IP20; Made in Germany |
| Power supply | 230 V option 90–277 V AC/DC (max 8.5 VA); 24 V option 24–90 V AC/DC (max 7 VA) |
Technical values are taken from the manufacturer's published documentation. Confirm against the current datasheet before ordering.