UMG 96-S2
Panel-mount energy analyzer
The UMG 96-S2 is a straightforward 96 mm panel meter for accurate energy and power readings without complex setup. It reads current, voltage and power values with high sampling accuracy, passes data to a BMS or PLC over Modbus, and supports both 1 A and 5 A CT wiring on TN/TT networks.
Key Features
- 01Simple configuration/operation from the switchboard front
- 02High sampling frequency for precise readings
- 03Compact 96 mm panel-mount housing
- 04Works with common 1 A and 5 A CTs on TN/TT networks
- 05Tariff switching for basic time-of-use tracking
- 06Bundled with GridVis-Basic visualization software
Applications
- Power Quality SolutionsPower quality problems such as harmonics, voltage sags and swells, flicker, transients and voltage unbalance can occur in electrical systems. They can arise from non-linear loads, sudden load changes, network events and the electrical structure of the facility itself. Poor power quality can cause overheating in equipment, nuisance tripping, energy losses, shorter equipment life and interruptions to production continuity. At EPKOM we use power quality analyzers to measure and monitor LV and MV systems, recording harmonics, voltage events and the other power quality parameters. We evaluate the resulting data against the relevant standards, such as EN 50160, IEC 61000 and IEEE 519, according to the measurement point and the scope of the application. Following measurement and analysis, we apply active and passive harmonic filters, SVG systems, compensation solutions and power quality monitoring systems according to the needs of the facility, helping the electrical infrastructure run more safely, efficiently and stably.
- Energy Monitoring SystemsEnergy monitoring systems measure and analyse electricity consumption continuously, at facility, feeder, department or machine level. Alongside electricity, other energy sources such as water, natural gas and compressed air can be tracked through the same system. Data from Janitza energy analyzers is collected centrally in the GridVis software, where consumption trends, load profiles and energy performance indicators can be followed. Automatic reporting and alarm functions make abnormal consumption and energy losses quick to identify. Energy monitoring systems help to allocate energy costs correctly, to identify inefficient points of consumption and to improve energy performance continuously. They also support ISO 50001 energy management processes and make it possible to track energy performance indicators such as PUE in data centers.
Technical Specifications
UMG 96-S2
| Measurement inputs | 4 voltage inputs (0–300 Vrms L-N, 0–425/520 Vrms L-L); 3 current inputs (1/5 A); 8 kHz/channel sampling |
|---|---|
| Accuracy class | Voltage/current 0.2%; active energy Class 0.5S (…/5A) |
| Communication protocols | RS485, Modbus RTU; 1 digital/pulse (S0) output |
| Display | Front-panel readout |
| Installation type | Front-panel/switchboard mount; 96 × 96 × 48 mm, ~250 g |
| Harmonics | 1st–15th order (V and A), THD-U/THD-I, power factor, frequency |
| Certifications / standards | IP40 front / IP20 rear (IP54 with seal); no MID/IEC 61557-12 certification found published |
| Power supply | 90–265 V AC / 90–250 V DC, 300 V CAT III; −10 °C to +55 °C |
Technical values are taken from the manufacturer's published documentation. Confirm against the current datasheet before ordering.