UMG 96-PQ-L
Compact panel-mount power quality analyzer
The UMG 96-PQ-L is a compact, 96×96 mm panel-mount analyzer focused on power-quality diagnostics rather than just basic metering, capturing detailed harmonic content, flicker, and disturbance events over the long term. A data-compression scheme lets it retain years of high-resolution trend data in onboard flash instead of only weeks, useful for tracking down intermittent quality problems after the fact.
Key Features
- 01Harmonics measurement to the 65th order
- 02280 sampling points/cycle; 20 ms RMS value memory for full-wave event capture
- 0350 configurable comparators / predefined threshold profiles
- 04Data compression enabling up to ~15 years of storage depth
- 05Optional Class S variant (flicker/interharmonic/rapid-voltage-change per EN 50160/IEC 61000-4-30)
- 06Oscilloscope function and phasor diagrams on-device
Applications
- Power Quality SolutionsPower quality problems such as harmonics, voltage sags and swells, flicker, transients and voltage unbalance can occur in electrical systems. They can arise from non-linear loads, sudden load changes, network events and the electrical structure of the facility itself. Poor power quality can cause overheating in equipment, nuisance tripping, energy losses, shorter equipment life and interruptions to production continuity. At EPKOM we use power quality analyzers to measure and monitor LV and MV systems, recording harmonics, voltage events and the other power quality parameters. We evaluate the resulting data against the relevant standards, such as EN 50160, IEC 61000 and IEEE 519, according to the measurement point and the scope of the application. Following measurement and analysis, we apply active and passive harmonic filters, SVG systems, compensation solutions and power quality monitoring systems according to the needs of the facility, helping the electrical infrastructure run more safely, efficiently and stably.
- Energy Monitoring SystemsEnergy monitoring systems measure and analyse electricity consumption continuously, at facility, feeder, department or machine level. Alongside electricity, other energy sources such as water, natural gas and compressed air can be tracked through the same system. Data from Janitza energy analyzers is collected centrally in the GridVis software, where consumption trends, load profiles and energy performance indicators can be followed. Automatic reporting and alarm functions make abnormal consumption and energy losses quick to identify. Energy monitoring systems help to allocate energy costs correctly, to identify inefficient points of consumption and to improve energy performance continuously. They also support ISO 50001 energy management processes and make it possible to track energy performance indicators such as PUE in data centers.
Technical Specifications
UMG 96-PQ-L
| Voltage inputs | L-N 0.01–600 Vrms, L-L 0.01–1,040 Vrms; 3P4W/3P3W/1-phase systems |
|---|---|
| Current inputs | 0.005–6 Arms nominal (5A), 0.1 mA resolution |
| Accuracy | Active power Class 0.5; reactive/apparent Class 1/0.5; energy Class 0.2/0.2S; V/I Class 0.2; frequency Class 0.05 |
| Harmonics | 1st–65th order; THD-U/THD-I |
| Communication protocols | RS-485 (Modbus RTU); optional Ethernet adds Modbus TCP/IP, Gateway, up to 5 simultaneous TCP connections |
| Display | Backlit color/graphic LCD, 6-button interface, oscilloscope function |
| Memory / data logging | 64 MB flash; up to ~15-year storage depth |
| Installation type | Panel mount, 96×96 mm, cut-out 92×92 mm, depth 87.2 mm |
| Certifications / standards | MID 2014/32/EU Class E2/M1; IEC 61000-4-30 Class S (option); IK07; UL/ANSI listed |
Technical values are taken from the manufacturer's published documentation. Confirm against the current datasheet before ordering.